The ActiveThree system is sold in versions with 8 up to 128 channels. A system in basic version consists of electrodes, AD-box, two batteries, battery charger, optical USB2 receiver, and LabVIEW acquisition software (executable and VI with source code). The price of a complete system including active electrodes, excluding headcaps is EUR 12,000 for the Base system plus EUR 200 per channel plus EUR 1280 per set of 32 electrodes. An upgrade to more channels is always possible at a later stage at a price of EUR 200 per channel. All systems bear a 3 year warranty (1 year on electrodes and batteries).
All prices are excluding VAT, in Euro) Click here to download the full price list in .pdf format.
 
The price of a system depends on the number of channels, below are some indicative prices:
8 channels hardware complete with active electrodes, plus acquisition software: approx: EUR 14,500
16+8 channels hardware complete with headcaps and active electrodes, plus acquisition software: approx: EUR 18,000
32+8 channels hardware complete with headcaps and active electrodes, plus acquisition software: approx: EUR 22,000
64+8 channels hardware complete with headcaps and active electrodes, plus acquisition software: approx: EUR 30,000
128+8 channels hardware complete with headcaps and active electrodes, plus acquisition software: approx. EUR 45,000
160+8 channels hardware complete with headcaps and active electrodes, plus acquisition software: approx. EUR 53,000
256+8 channels hardware complete with headcaps and active electrodes, plus acquisition software: approx. EUR 76,000 (ActiveTwo only)

 

ActiveThree system and parts specific for the Active3:
ActiveThree Base system 12000  

The Active3 Base system includes the following:
- AD-box
- 0 x Amplifier/converter module (no channels are included with the Base system)
- 6 x pre-installed universal, auto configuring AUX input.
- 2 x Rechargeable battery cell 18650
- Charger
- Optical fiber (SC-SC 10 meter)
- USB2 Receiver (new red model, including USB cables)
- Carrying suitcase and cablerack
- LabVIEW acquisition software

Amplifier module for Active3 (8 amplifier channels) 1600   For example: An AD-box with 64+8 channels needs 8+1 modules
MK3-1020-16 electrode set, 1020 640   16 channel A-set for a 16 channel AD-box
MK3-1020-32 electrode set, 1020 1280   32 channel A-set for a 32 channel AD-box
MK3-1020-64A electrode set, 1020 1280   32 channel A-set for a 64 channel AD-box. (left side/half of the headcap)
MK3-1020-64B electrode set, 1020 1280   32 channel B-set for a 64 channel AD-box. (right side/half of the headcap)
MK3-ABC-A electrode set, ABC 1280   32 channel A-set. Labelling: A1-A32
MK3-ABC-B electrode set, ABC 1280   32 channel A-set. Labelling: B1-B32
MK3-ABC-C electrode set, ABC 1280   32 channel A-set. Labelling: C1-C32
MK3-ABC-D electrode set, ABC 1280   32 channel A-set. Labelling: D1-D32
CMSDRL PIN A3 200   160 cm cord with CMS and DRL electrodes. CMS=PIN, DRL=PIN
CMSDRL FLAT A3 200   160 cm cord with CMS and DRL electrodes. CMS=FLAT, DRL=FLAT
ABR A3 1600   ActiveThree ABR electrode set (connects to any of the 6 AUX inputs)
Audio Optical cable 1000   ActiveThree Audio Optical cable (connects to any of the 6 AUX inputs)
ERGO connector cable 300   ActiveThree cable with free inputs box (connects to any of the 6 AUX inputs)
Galvanic skin response A3 500   ActiveThree GSR cord (connects to any of the 6 AUX inputs)
Microphone A3 200   ActiveThree Microphone (connects to any of the 6 AUX inputs)
Photo sensor A3 200   ActiveThree Photosensor (connects to any of the 6 AUX inputs)
Plethysmograph Finger A3 200   ActiveThree Plethysmograph sensor (connects to any of the 6 AUX inputs)
Respiration belt A3 500   ActiveThree Respiration belt (connects to any of the 6 AUX inputs)
Response Switch A3 200   ActiveThree Response Switch (connects to any of the 6 AUX inputs)
Temperature Skin A3 200   ActiveThree Temperature sensor (connects to any of the 6 AUX inputs)
       

 

Active2.5 specific parts: (the Active2.5 system is only sold for High density EMG and for more than 128+8 channels)
Amplifier module for Active2 (8 amplifier channels) 1600   For example: An AD-box with 64+8 channels needs 8+1 modules
MK3-1020-16 electrode set, 1020 640   16 channel A-set for a 16 channel AD-box
MK3-1020-32 electrode set, 1020 1280   32 channel A-set for a 32 channel AD-box
MK3-1020-64A electrode set, 1020 1280   32 channel A-set for a 64 channel AD-box. (left side/half of the headcap)
MK3-1020-64B electrode set, 1020 1280   32 channel B-set for a 64 channel AD-box. (right side/half of the headcap)
MK3-ABC-A electrode set, ABC 1280   32 channel A-set. Labelling: A1-A32
MK3-ABC-B electrode set, ABC 1280   32 channel A-set. Labelling: B1-B32
MK3-ABC-C electrode set, ABC 1280   32 channel A-set. Labelling: C1-C32
MK3-ABC-D electrode set, ABC 1280   32 channel A-set. Labelling: D1-D32
MK3-ABC-E electrode set, ABC 1280   32 channel A-set. Labelling: E1-E32
MK3-ABC-F electrode set, ABC 1280   32 channel A-set. Labelling: F1-F32
MK3-ABC-G electrode set, ABC 1280   32 channel A-set. Labelling: G1-G32
MK3-ABC-H electrode set, ABC 1280   32 channel A-set. Labelling: H1-H32
CMSDRL PIN 200   160 cm cord with CMS and DRL electrodes. CMS=PIN, DRL=PIN
CMSDRL FLAT 200   160 cm cord with CMS and DRL electrodes. CMS=FLAT, DRL=FLAT
ABR (Auditory Brainstem Response) (input + cord) 3000   ActiveTwo ABR electrode set + dedicated ABR input
ABR Cord (cord only) 500   ActiveTwo ABR electrode set
Analog Input Box (including 8 channels) 4000   For measuring signals from not isolated sources.
Battery-box (spare Battery-box) 550   The Battery-box has 1 internal battery cell (Cyclon cell) which is easily replacable.
Charger (spare Charger) 550   The Charger is including an ACDC adapter.
Cyclon cell 150   Replacement battery cells for Battery-box
Ergo input (needed for Microphone & Photo cell) 400   Needed for Microphone, Photosensor or Response switch.
Ergo input Dual (2 x bi-polar Ergo input) 800   2 Ergo inputs, so you can connect 2 sensors simultaneously.
Galvanic skin response (Input + cord) 1125   ActiveTwo GSR cord + dedicated GSR input
Galvanic skin response Cord (cord only) 150   ActiveTwo GSR cord
Hyperscanning for Active2.5 1000   Optical Daisy-chain input on the AD-box. Up to 4 boxes can be optically daisy-chained.
Microphone (excluding Ergo input) 200   ActiveTwo Microphone
Photo sensor (excluding Ergo input) 150   ActiveTwo Photosensor
Plethysmograph Finger (Input + sensor) 900   ActiveTwo Plethysmograph sensor + dedicated Plethysmograph input
Plethysmograph Finger sensor (sensor only) 700   ActiveTwo Plethysmograph sensor
Respiration belt (Input + cord) 1125   ActiveTwo Respiration belt + dedicated Respiration input
Respiration belt Cord (cord only) 400   ActiveTwo Respiration belt
Response Switch (Ergo Input + cord) 475   ActiveTwo Response Switch + Ergo input
Response Switch Cord (cord only) 75   ActiveTwo Response Switch
Temperature Skin (Input + cord) 1100   ActiveTwo Temperature sensor + dedicated Temperature input
Temperature Skin cord (cord only) 300   ActiveTwo Temperature sensor
USB2 Receiver 1400   Newest red color model of the USB Interface.
       

 

Active2 specific parts: (the Active2 system is not sold anymore, parts will continue to be available for many years)
Amplifier module for Active2 (8 amplifier channels) 1600   For example: An AD-box with 64+8 channels needs 8+1 modules
P32-1020-16 electrode set, 1020 640   16 channel A-set for a 16 channel AD-box
P32-1020-32CMS electrode set, 1020 1280   32 channel A-set for a 32 channel AD-box. Including CMSDRL
P32-1020-32 electrode set, 1020 1280   32 channel A-set for a 32 channel AD-box.
P32-1020-64ACMS electrode set, 1020 1280   32 channel A-set for a 64 channel AD-box. (left side/half of the headcap) Including CMSDRL
P32-1020-64A electrode set, 1020 1280   32 channel A-set for a 64 channel AD-box. (left side/half of the headcap)
P32-1020-64B electrode set, 1020 1280   32 channel B-set for a 64 channel AD-box. (right side/half of the headcap)
P32-ABC-ACMS electrode set, ABC 1280   32 channel A-set. Labelling: A1-A32. Including CMSDRL
MK3-ABC-A electrode set, ABC 1280   32 channel A-set. Labelling: A1-A32
MK3-ABC-B electrode set, ABC 1280   32 channel A-set. Labelling: B1-B32
MK3-ABC-C electrode set, ABC 1280   32 channel A-set. Labelling: C1-C32
MK3-ABC-D electrode set, ABC 1280   32 channel A-set. Labelling: D1-D32
MK3-ABC-E electrode set, ABC 1280   32 channel A-set. Labelling: E1-E32
MK3-ABC-F electrode set, ABC 1280   32 channel A-set. Labelling: F1-F32
MK3-ABC-G electrode set, ABC 1280   32 channel A-set. Labelling: G1-G32
MK3-ABC-H electrode set, ABC 1280   32 channel A-set. Labelling: H1-H32
CMSDRL PIN 200   160 cm cord with CMS and DRL electrodes. CMS=PIN, DRL=PIN
CMSDRL FLAT 200   160 cm cord with CMS and DRL electrodes. CMS=FLAT, DRL=FLAT
ABR (Auditory Brainstem Response) (input + cord) 3000   ActiveTwo ABR electrode set + dedicated ABR input
ABR Cord (cord only) 500   ActiveTwo ABR electrode set
Analog Input Box (including 8 channels) 4000   For measuring signals from not isolated sources.
Battery-box (spare Battery-box) 550   The Battery-box has 1 internal battery cell (Cyclon cell) which is easily replacable.
Charger (spare Charger) 550   The Charger is including an ACDC adapter.
Cyclon cell 150   Replacement battery cells for Battery-box
Ergo input (needed for Microphone & Photo cell) 400   Needed for Microphone, Photosensor or Response switch.
Ergo input Dual (2 x bi-polar Ergo input) 800   2 Ergo inputs, so you can connect 2 sensors simultaneously.
Galvanic skin response (Input + cord) 1125   ActiveTwo GSR cord + dedicated GSR input
Galvanic skin response Cord (cord only) 150   ActiveTwo GSR cord
Hyperscanning for Active2.5 1000   Optical Daisy-chain input on the AD-box. Up to 4 boxes can be optically daisy-chained.
Microphone (excluding Ergo input) 200   ActiveTwo Microphone
Photo sensor (excluding Ergo input) 150   ActiveTwo Photosensor
Plethysmograph Finger (Input + sensor) 900   ActiveTwo Plethysmograph sensor + dedicated Plethysmograph input
Plethysmograph Finger sensor (sensor only) 700   ActiveTwo Plethysmograph sensor
Respiration belt (Input + cord) 1125   ActiveTwo Respiration belt + dedicated Respiration input
Respiration belt Cord (cord only) 400   ActiveTwo Respiration belt
Response Switch (Ergo Input + cord) 475   ActiveTwo Response Switch + Ergo input
Response Switch Cord (cord only) 75   ActiveTwo Response Switch
Temperature Skin (Input + cord) 1100   ActiveTwo Temperature sensor + dedicated Temperature input
Temperature Skin cord (cord only) 300   ActiveTwo Temperature sensor
USB2 Receiver 1400   Newest red color model of the USB Interface.
       

 

Spare parts for all systems (Active3, Active2.5 & Active2):
USB Trigger Interface
100   Used for sending triggers from the stimulation PC to the acquisition PC
USB Trigger Interface + Hyperscanning
500   The same as the standard USB Trigger Interface, but with the added option of Hyperscanning (simultaneous measurement of multiple AD-boxes)
8 Touch-proof Active FLAT electrodes 400   8 x TP FLAT electrode
8 Touch-proof Active PIN electrodes 400   8 x TP PIN electrode
16 channel headcap (all sizes) 280   Headcap with 16 electrode holders.
32 channel headcap (all sizes) 360   Headcap with 32 electrode holders.
64 channel headcap (all sizes) 520   Headcap with 64 electrode holders.
128 channel headcap (all sizes) 840   Headcap with 128 electrode holders.
160 channel headcap (all sizes) 1000   Headcap with 160 electrode holders.
256 channel headcap (all sizes) 1480   Headcap with 256 electrode holders.
Adhesive disks 13x5 mm (reel of 500) 80   For sticking TP FLAT electrodes to the skin. Use with ten20 gel for EMG/ECG.
Adhesive disks 20x5 mm (reel of 500) 80   For sticking TP FLAT electrodes to the skin. Use with ten20 gel for EMG/ECG.
Adhesive disks 20x8 mm (reel of 500) 80   For sticking TP FLAT electrodes to the skin. Use with ten20 gel for EMG/ECG.
ECG BSM Carbon electrode panel2x12 2000   Body Surface Mapping panel for High Density ECG measurements
ECG BSM Carbon electrode panel4x8 4000   Body Surface Mapping panel for High Density ECG measurements
Electrode holder for headcap (mounted) 10   Electrode holder mounted in headcap (11mm, 14mm or 17mm) at custom location.
Electrode holders for headcap (not mounted) 4   Spare electrode holder, NOT mounted in headcap (11mm, 14mm or 17mm)
Empty headcap 200    
Headbox ACT32 1000   Headbox with 32 TouchProof inputs.
Jazz eye tracker system integrated with ActiveTwo 8000    
Optical fiber 100   10 meter long. ST-ST or SC-ST or SC-SC
Replace fiber receptacle on AD-box or receiver 200   In the case that the fiber output of your AD-box is broken, we can replace that part.
Replacement of an electrode on an electrode set For free   Electrode set will be repaired for free when the set is still in good condition
Signa Electrode gel 12   Tube of 250 gram Parker Signa gel. Advised for EEG electrodes.
Syringe 1   Blunt needle
Ten20 50   Jar of 114 gram. Advised for EMG/ECG/GSR electrodes
       

 

Software
BESA    
BESA is the most widely used software for source analysis and dipole localization in EEG and MEG research    
- Besa Basic: Review & Averaging 5.750  
- Besa Standard: Basic + 'Source Analysis' 13.200  
- Besa Complete: Basic + 'Source Analysis' + 'Coherence Analysis' 18.360  
     
EMSE    
4D multimodal functional brain imaging, including analysis, source estimation, image processing, and visualization.    
- Locator 1900  
- Data editor 2200  
- Source estimator 4000  
- MR Viewer 2200  
 
Note 1: Modules, Active electrodes and other BioSemi accessories can only be used with the ActiveTwo Base-system, therefore these parts are only sold to existing ActiveTwo users and are not sold separately.
Note 2: Use the above prices as a guideline, for some countries additional surcharges have to be considered because of local taxes, shipping, additional insurance costs, and the extra costs of a local service/support network. Please ask us or your local dealer for a quotation.
Note 3: Minimum order amount for parts and maintenance (Gel, adhesive disks) is 150 euro.
   
  All BioSemi products are for research applications only. Not sold as a medical device as defined in EU directive 93/42/EEC. Not designed or intended to be used for diagnosis or treatment of disease.